Heating, cooling and domestic hot water
Single phase with soft starter
Optional part: Internal 3 KW electric heater and hot water pump
Adopt Siemens controller
Varied heat curve
SWEP plate heat exchanger
Galvanized sheet case.
Stainless steel 443 case is optional
| AIR TO WATER HEAT PUMP |
AW09/B |
AW10/B |
| Heat output/Power consumption at 7/35℃ |
kW |
9.5/2.6 |
11.0/2.9 |
| Heat output/Power consumption at 7/45℃ |
kW |
9.1/3.0 |
10.5/3.3 |
| Heat output/Power consumption at 7/55℃ |
kW |
8.8/3.8 |
10.2/4.1 |
| Heat output/Power consumption at 2/35℃ |
kW |
8.2/2.5 |
9.5/2.8 |
| Heat output/Power consumption at 2/45℃ |
kW |
7.9/3.0 |
9.2/3.4 |
| Heat output/Power consumption at -7/35℃ |
kW |
6.2/2.5 |
7.2/2.8 |
| Heat output/Power consumption at -7/45℃ |
kW |
6.1/3.0 |
7.1/3.4 |
| Cool output/Power consumption at 35/7℃ |
KW |
7.8/2.9 |
9.5/3.3 |
| Starting current |
A |
30 |
46 |
| Soft-start relay |
|
Included as standard |
|
| Power |
|
220-240V/1PH/50Hz |
380-415V/3PH/50Hz |
| Compressor |
|
DAIKIN Scroll |
HITACHI scroll |
| Condenser |
|
Swep Brazed plate heat exchanger |
| Nominal flow heating medium |
l/s |
0.45 |
0.52 |
| Internal pressure drop at nominal flow |
kPa |
18 |
24 |
| Air flow |
m3/h |
3000 |
3000 |
| Nominal output fan |
W |
220 |
220 |
| Max outgoing heating medium temperature |
℃ |
55℃ |
| Dimensions(HxWxD) |
mm |
1050x1050x450 |
1050x1050x450 |
| Pipe connector |
|
DN25 |
| Weight |
kg |
125 |
125 |
| The above data is tested by EN14511 |